Glossary-2 PerSeptive Biosystems
G
O
S
S
L
A
R
Y
Glossary
Delay Time
—Used in Delayed
Extraction mode. Time in nanoseconds
(after the laser ionizes the sample) at
which full Accelerating Voltage is
applied, creating the potential gradient
that accelerates ions.
Digitizer
—A device that converts
an analog signal to a digital word and
stores the result in memory. This allows
the transfer of the digitized signal to a
computer for additional processing.
Dimer
—A species that results from a
association between two identical
molecules. Expressed as [2M+H]
+
.
Appears in a mass spectrum at 2 times
the protonated molecular ion mass,
minus one mass unit.
Edman degradation
technique
—An approach to
amino-end-group determination
involving the use of a reagent,
phenylisothiocyanate, that can be
applied to the liberation of a derivative
of the amino-terminal residue without
hydrolysis of the remainder of the
peptide chain.
Flight tube
—Vacuum chamber in
which ions drift from the source to the
detector.
Fore pump
—Rotary pump that
maintains vacuum in the sample loading
chamber, creates the low-vacuum
condition needed by the turbo pump,
and provides backing pressure to the
turbo pump.
Fragment
—Ion dissociated from
precursor ion.
FWHM
—Full width at half maximum.
GPMAW
—General Protein/Mass
Analysis for Windows software, a
software program used to identify
protein sequences.
Grid voltage
—Secondary voltage
used to fine
-
tune ion acceleration, on a
variable-voltage grid above the sample
plate.
Guide Wire voltage
—Voltage
applied to beam guide wire to focus ions
on detector. Particularly useful for
enhancing analysis of high mass ions.
Immonium ion
—In PSD, low
molecular weight fragment ions derived
from amino acids.
Initial velocity
—The velocity
associated with an ion when it is
released from the sample plate, before
acceleration. Voyager software allows
correction for matrix-dependent initial
velocities.
Intensity (signal or ion)
Amplitude of signal shown on
oscilloscope screen or spectrum
window.
Intensity (laser)
—Amount of
laser-generated light reaching the
sample spot. Controlled by adjusting the
laser attenuator using laser step setting.
Ion
—An isolated electron or proton or
an atom or molecule which, by loss or
gain of one or more electrons, has
acquired a net electric charge.
Vista de pagina 567